1br a 15 a 1 bed room will accommodate one patient for the delivery of nursing and medical care and treatment.
Standard medical exam room size.
Standardized exam consultation room layout e g standardization of supplies stocked same handed rooms citation.
Seating capacity of 7 patient other rooms.
Acoustic privacy required body protected electrical area area m2.
Ft long waiting room.
Requires ability to view out of the window from either chair or bed.
Unmh standards require 100 sf min.
Each single patient exam room shall have a minimum 80 square feet clear floor area with 2 feet 8 inches clear at each side and foot of exam table.
Standard components room data sheets room code.
Exam room layout that facilitates physical exam and other procedures e g exam table angled away from walls physician at patient s right side physician s easy access to diagnostic instruments.
Examination rooms shall include an exam table recliner or chair placed at an angle.
Natural light and outlook essential.
A minimum ceiling height of 3000mm is required in operating rooms interventional imaging rooms and birthing rooms.
Once you have estimated your square footage be sure to fill out the form to the right so we can help you make your dream medical office space a reality.
Unless specified elsewhere if an examination room is provided it shall have a minimum clear floor area of 120 square feet the least dimension of which shall be 10 feet.
If x rays are performed in the exam room osha regulations require the equipment to be labeled with caution signs and limiting employee exposure to radiation by supplying personal radiation.
5 ft wide and 72 5 sq.
Please note the medical office square foot calculator adds approximately 35 to the total square footage to account for any common areas loss factor or construction needs walls doorways.
2 doctors offices janitors room ada rest room lab vitals room managers office nurse station.
Exam room 12 100 1 200 minimum floor area of 80 square feet required.
Ceiling mounted equipment must be able to achieve the required clearance height of 2150mm when in the stowed position especially within circulation areas.
2 8 clearance at each side and at the foot of exam table.
Each room should have enough space to comfortably.
Provide sink and counter for writing.
The optimal size for an exam room is 10 feet by 10 feet although these dimensions can vary slightly without affecting the function of the room.